Instructions for the Installer
5.7Adjusting the minimum setting for natural gas and town gas
Reassemble the components on the burner and fit the knobs onto the tap rods.
Light the burner and turn it to the minimum setting . Remove the knob again and adjust the regulator screw inside or beside the tap rod (depending on the model) until an even minimum flame is obtained.
Put the knob back in place and check the stability of the burner flame (the flame must not go out when the knob is turned quickly from the maximum to the minimum setting).
5.8Adjusting the minimum for bottled gas
To adjust the minimum level when using bottled gas, the adjuster screw inside or beside the tap rod must be turned fully clockwise (depending on the models).
The diameters of the bypasses for each individual burner are stated in point “5.2 Adjusting for bottled gas".
After adjusting for use of a gas other than the gas used for testing the appliance, replace the label on the casing with the label for the new gas. The label is supplied in the bag with the LPG nozzles (G30 ˆ G31).
5.9Hob burner layout
Burner type
1 Auxiliary
2 Semi rapid
3 Rapid
4 Double flame
5 Ultra rapid
6 Rapid
7 Rapid
8 Double flame
5.10Greasing the gas taps
Over time, the gas taps may become stiff or jam. Clean their insides and change their
lubricating grease. This operation must be carried out by a skilled technician.
29