GB

Hood description

1)Motor speed switch

2)Light switch

3)Removable drawer

4)Suction grid

5)Hob light

Opening the grid

Move tabs E inwards (Fig.1).

Pull the grid slightly outwards and turn it

downwards.

To remove the grid, slide it out from the right- hand side until the grid is unhooked (Fig.2).

Removing the drawer-piece

Push release button S and pull the front panel door frontwards (release first by a side, then by the other) (Fig. 1).

Fitting the removable drawer

— Fit the door snugly into guides R (Fig.3).

Use

Two systems are available:

External exhaust system

Internal recycle system

External exhaust system

Air is expelled by a duct which must be connected to coupling ring C (Fig.4). Lever G is positioned on setting "A" (Fig.5).

If the hood is provided with carbon filter, it must be removed (fig. 2).

Internal recycle system (filtering)

Air is filtered through a carbon filter and then pumped back into the room through the front grid. This version is used when the room has no external discharge pipe and it is not possible to install one. In order to use this version of the hood, proceed as follows:

Turn lever G to setting "F" (Fig.2).

If no filter is supplied with the hood, ask the technical assistance service or manufacturing company for one and specify the hood model.

To install the filter, insert it so that point E matches up with arrow D (Fig.2) and turn the arrow clockwise until it locks.

Installation

When installed. the hood must be not less than 65 cm. above electric burners or 75 cm. above gas or mixed-fuel burners.

In the vented exhaust version the fumes outlet duct must be 100 mm. or 120 mm in diameter according to the coupling ring supplied. In the horizontal runs the duct must be slightly slanted (about 10°) and directed upwards to vent the air easily from the room to the outside.

Electric connection

Before completing any connection, make sure the house voltage corresponds with the voltage indicated on the label affixed inside the hood.

The hood is supplied with a standard plug; connect it to a correspondingly standard socket. In the case is intended to connect the appliance permanently to the mains after having removed the plug supplied, must be fitted a two-pole switch conforming to regulations with an opening distance between contacts of not less than 3mm The manufacturers are not liable for any problems caused by the user’s failure to observe the above instructions.

Fastening the removable drawer

Fasten the removable drawer N using the six 2.9x16 screws U supplied in the accessory kit (Fig.1).

Remove the door to simplify this operation.

Fastening the hood to the wall cupboard

Make a hole in the bottom of the cupboard as shown in Fig.6 (do not consider the thickness of the wooden panel).

In vented exhaust hoods, make a Ø115mm hole (with pipes of Ø 100mm) or 135 mm hole (with pipes of Ø 120mm), both on the bottom and top of the cupboard for the discharge pipe. From inside the cupboard, insert the four 4,2x35 screws M supplied in the accessory kit (Fig.7) and screw them to the top of the hood.

If the cupboard is deeper than the hood , insert spacer P and fix it with 2 screws to the back of the hood.

7

Page 7
Image 7
Smeg KSEIR70 manual Use, Installation