![Activated charcoal filter (Recirculation version)](/images/new-backgrounds/71843/7184321x1.webp)
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
•The filter is not washable and cannot be regenerated. It must be replaced when led S2 flashes or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on.
Alarm signal reset
•Switch off the lights and extractor motor.
•Press button V3 for at least 3 seconds, until the leds start to flash.
Replacing the Filter
•Remove the metal grease filters
•Remove the saturated activated carbon filter by releasing the fixing hooks
•Fit the new filter by hooking it into its seating
•Replace the metal grease filters.
Alarm signal activation
•On the recirulcation version extractor hood, the filter saturation alarm is activated during installation or at a later date.
•Switch off the lights and extractor motor.
•Press button V3 for at least 10 seconds, until the leds start to flash:
•2 flashes of the activated carbon odour filter saturation alarm led = filter ACTIVATED
•1 flash of the activated carbon odour filter saturation alarm led = filter DEACTIVATED
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the 2 screws fixing the ring nut.
• Extract the lamp from the lamp holder by pulling gently.
•Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.
•Replace the ring nut and fix it in place using the two screws removed as above.
GB |
| 21 |