CLOSING ELEMENT
•The space between the edge of the hood and the rear wall can be closed by applying the element 20 provided, using the screws supplied for this purpose.
20
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer.
• | Fix the pipe in position using sufficient pipe |
|
• | clamps (not supplied). | ø150 |
Remove any activated charcoal filters. |
|
| RECIRCULATION VERSION AIR OUTLET |
|
• | Cut a hole ø 150 mm in the wall unit over the | 150 |
| hood. | |
|
| |
• Connect the hood body outlet to the top part of |
| |
| the wall unit using a rigid or flexible pipe ø 150 |
|
| mm, to be selected by the installer. |
|
• | Fix the pipe in position using sufficient pipe |
|
| clamps (not supplied). |
|
• | Ensure that the activated charcoal filters have |
|
| been inserted. |
|
ELECTRICAL CONNECTION
•Connect the hood to the mains through a
•When opening the sliding carriage for the first time after installing the hood, pull it out briskly until it clicks.