MAINTENANCE
Grease filters
CLEANING METAL GREASE FILTERS
•The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage.
• Remove the filters, one at a time, after disconnecting the relative fastening elements.
•Wash the filters, taking care not to bend them. Allow them to dry before refitting.
•When refitting the filters, make sure that the handle is visible on the outside.
Odour filters (Recirculation version)
REPLACING ACTIVATED CHARCOAL FILTERS
•These filters are not washable and cannot be regenerated, and must be replaced approximately every four months of operation, or more frequently with heavy usage.
•Remove the grease filters.
•Remove the saturated activated charcoal filters, as shown (A).
•Fit new filters ( B), as shown.
•Replace the grease filters.
B
A
Lighting
LIGHT REPLACEMENT
•20 W halogen light.
•Remove the 2 Screws fixing the Lighting support, and pull it out of from the Hood.
• Extract the Lamp from the Support.
• Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.
• Replace the Support, fixing it in place with the two Screws removed as above.
GB |
| 15 |