Instructions for the installer

2 POSITIONING OF THE HOB

It is the law that all gas appliances are installed by authorised persons. Clearance around the appliance must comply with the requirements of AGA601.

The following operation requires building and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood as long as they are heat resistant (T 90°C).

2.1 Attachment to the support structure

Create an opening with the dimensions shown in the figure in the top surface of the counter, keeping a minimum distance of 50 mm from the rear border.

This appliance is classified as “type Y” in relation to fire hazards and can therefore be mounted against walls higher than the work surface on condition that a certain distance “X” be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating. Make sure there is a minimum of 600 mm between the hot plate flames and any shelf that may be installed directly above them.

In case of installation on a hollow compartment with doors, a separating panel has to be placed under the hob. Keep a minimum distance of 10 mm between the bottom of

the unit and the panel surface. The panel has to be easily removable to allow access

in the event of technical service.

6

Page 4
Image 4
Smeg PA106SX manual Instructions for the installer, Positioning of the HOB, Attachment to the support structure