Smeg PGF75BE3, PGF75-3 Adjustment To Different Types Of Gas, Replacement of nozzles on the hob

Models: PGF75-3 PGF75BE3

1 16
Download 16 pages 30.08 Kb
Page 10
Image 10
3 ADJUSTMENT TO DIFFERENT TYPES OF GAS

Instructions for the installer

3 ADJUSTMENT TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, unplug the appliance from the mains.

The hob is set for natural gas G20 (2H) at a pressure of 20 mbar. In the case of functioning with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below.

3.1Replacement of nozzles on the hob

1.Remove the grids and all the caps and flame-spreader crowns;

2.Unscrew the burner nozzles with a 7 mm socket wrench;

3.Replace the nozzles according to the type of gas to be used (see paragraph “3.2 Burner and nozzle characteristics table”).

4.Replace the burners in the correct position.

Nozzles for town gas (G110 – 8 mbar) are available from authorized assistance centres.

28

Page 10
Image 10
Smeg PGF75BE3 Adjustment To Different Types Of Gas, Replacement of nozzles on the hob, Instructions for the installer