Instructions for the installer
3.2Burner and nozzle characteristics table
Burner
Auxiliary (1)
Semi rapid (2)
Ultra Rapid (3)
Rated
heating
capacity
(kW)
1.05
1.75
4.0
LPG – G30/G31 30/37 mbar
| Nozzle |
|
| Reduced |
| Flow rate |
| Flow rate |
| ||||
| diameter |
|
|
|
| mm |
| flow rate |
| g/h G30 |
| g/h G31 |
|
| 1/100 mm |
|
| 1/100 |
| (W) |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||||
| 50 |
| 30 * |
|
| 27/28 ** |
| 400 |
| 76 |
| 75 |
|
|
|
|
|
|
|
|
| ||||||
| 65 |
| 33 * |
|
| 32/33 ** |
| 500 |
| 127 |
| 125 |
|
|
|
|
|
|
|
|
| ||||||
| 100 |
| 63 * |
|
| 63/65 ** |
| 1600 |
| 291 |
| 286 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown in point "4.1 Adjusting the minimum setting for natural gas".
Burner
Auxiliary (1)
Semi rapid (2)
Ultra Rapid (3)
Rated
heating
capacity
(kW)
1.05
1.75
4.0
Natural gas – G20 20 mbar
Nozzle diameter |
| Reduced flow rate |
1/100 mm |
| (W) |
|
|
|
72 | 400 | |
|
|
|
97 | 500 | |
|
|
|
135 |
| 1600 |
3.3Arrangement of burners on cooking hob
BURNERS
1. Auxiliary
2. Semi rapid
3. Ultra rapid
29