Rev 0.0 35
USER INSTRUCTIONS EN
5.2 Cleaning the water intake fi lter
Clean the water inlet fi lter at regular intervals. After closing the delivery tap,
unscrew the ring nut (ref. A fi g. 5-01) on the water inlet pipe (using a pair of pli-
ers, if necessary) and delicately clean the fi lter, removing deposits or impurities.
Then fi rmly fi x the pipe by tightening the ring nut (ref. A fi g. 5-01) (use a pair of
pliers, if necessary).
A
5.3 Cleaning the spray arms
The spray arms can be easily removed for periodic cleaning of the nozzles,
to prevent possible clogging. Wash them under running water (at room tem-
perature) and carefully replace them in their seats, checking that their rotary
movement is in no way impeded; if this is not the case, make sure they have
been mounted properly.

Removing the spray arms

To remove the upper spray arm (ref. A fi g. 5-02), unscrew the locking ring
(ref. B fi g. 5-02) by turning it clockwise. After cleaning, remount the spray
arm in its seat and tighten the locking ring by turning it anti-clockwise.
To remove the lower spray arm (ref. A fi g. 5-03), simply lift it up, pulling by the
central part (see fi g. 5-03). To remove the orbital spray arm assembly (ref. A
g. 5-04), take hold of the lower arm (ref. B fi g. 5-04) and pull the orbital
unit upward (see fi g. 5-04). After cleaning, remount the orbital spray arm in
its seat and push it down slightly until it clicks into place on the lower spray
arm (see fi g. 5-04). Then remount the lower spray arm into its seat and push
it down slightly until it click into place (see fi g. 5-03).
Fig. 5-01