Instructions for the installer

 

 

 

 

 

 

 

 

 

10.2 Burner and nozzle characteristics table

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED

 

 

 

 

 

 

 

Burner

HEATING

 

 

LIQUID GAS – G30/G31 28/37 mbar

CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(KW)

 

 

 

 

 

 

 

 

 

 

 

Nozzle

 

By-pass

Reduced

Flowrate

 

Flowrate

 

 

 

 

diameter

 

flowrate

 

 

 

 

 

 

1/100 mm

g/h G30

 

g/h G31

 

 

 

 

1/100 mm

(W)

 

 

 

 

 

 

 

 

 

Auxiliary (1)

1.05

50

 

30

400

76

75

Rapid (2)

2.5

79

 

42

800

182

179

Ultra-rapid int. (3)

0.9

46

 

30

400

65

64

Ultra-rapid ext. (4)

3.6

68+68

 

63

1600

262

257

 

 

 

RATED

 

 

 

 

 

 

 

Burner

HEATING

 

 

NATURAL GAS – G20 20 mbar

 

 

CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(KW)

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

Reduced

flowrate

 

 

 

 

 

1/100 mm

 

(W)

Auxiliary (1)

1.05

 

 

72

 

400

 

Rapid (2)

2.5

 

 

108

 

800

 

Ultra-rapid int. (4)

0.9

 

 

70

 

400

 

Ultra-rapid ext. (4)

3.6

 

 

102+102

 

1600

 

 

 

 

 

 

To identify the burners on your cooker hob, refer to the drawings in point

 

 

"4. KNOW YOUR APPLIANCE".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

39

Page 18
Image 18
Smeg PS906 manual Burner and nozzle characteristics table, Liquid GAS G30/G31 28/37 mbar