Instructions for the installer
4.2 Regulation for LPG
Loosen screw A and push air regulator B to the bottom.
With a 7 mm wrench, remove nozzle C and replace it with the proper one (follow the instructions on the reference tables for the type of gas to be used).
The torque wrench setting of the nozzle must not exceed 3 Nm. Regulate the air by sliding regulator B until reaching distance “X” shown in the table in paragraph “4.4 Regulation of primary air”.
Lock regulator B by tightening screw A.
|
|
|
|
|
|
| LPG – 2.75 kPa |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Burner |
|
|
|
|
|
|
|
|
|
|
|
|
| Nominal gas |
|
|
| Injector |
|
| ||
|
|
|
| consumption |
|
| consumption |
| (mm) |
|
|
|
|
|
| (MJ/h) |
|
| (MJ/h) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Auxiliary |
|
| 5.3 |
| 1.5 |
| 0.62 |
|
| |
|
|
|
|
|
|
|
|
|
| ||
| Semi rapid |
| 6.6 |
| 1.5 |
| 0.70 |
|
| ||
|
|
|
|
|
|
|
|
|
| ||
| Rapid |
| 9.0 |
| 3.2 |
| 0.82 |
|
| ||
|
|
|
|
|
|
|
|
|
| ||
| Wok |
| 15.0 |
| 5.4 |
| 1.05 |
|
|
4.3 Adjustment for natural gas
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
To allow the unit to work back with this type of gas, after it has been adjusted for LPG, perform the same operations described in paragraph “4.2 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph “4.4 Regulation of primary air”.
|
|
|
|
|
| NG – 1.0 kPa |
|
|
|
| Burner |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Nominal gas |
|
|
| Injector |
| ||
|
|
| consumption |
|
| consumption |
| (mm) |
|
|
|
| (MJ/h) |
|
| (MJ/h) |
|
|
|
|
|
|
|
|
|
| |||
| Auxiliary |
| 5.3 |
| 1.4 |
| 1.00 |
| |
|
|
|
|
|
|
| |||
| Semi rapid |
| 6.6 |
| 1.4 |
| 1.15 |
| |
|
|
|
|
|
|
|
|
|
|
| Rapid |
| 9.0 |
| 2.4 |
| 1.35 |
| |
|
|
|
|
|
|
|
|
|
|
| Wok |
| 15.0 |
| 4.3 |
| 1.75 |
|
12