Instructions for the Installer

5.2 Adjusting for bottled gas

Undo the screw C and push the air regulator D fully down.

Remove the nozzle E with a 7 mm spanner and fit the suitable one, following the instructions in the tables referring to the type of gas to be used. The nozzle must not be tightened with a torque of more than 3 Nm.

Regulate the air flow by sliding the regulator D along until the distance “X” stated in point "0

Adjusting the primary air flow” is obtained. Fix the regulator D by tightening the screw C.

Rated

BurnerheatBottled gas – G30/G31 30/37 mbar capacity

(kW)

 

 

 

 

Nozzle

 

By-pass

 

Reduced

 

Flow

 

Flow

 

 

 

 

diameter

 

mm

 

heat

 

rate g/h

 

rate g/h

 

 

 

 

1/100 mm

 

1/100

 

capacity

 

G30

 

G31

 

 

 

 

 

 

 

 

(W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

1.05

 

48

 

30

 

400

 

76

 

75

 

 

 

 

 

 

 

 

 

Semi rapid

 

1.7

 

62

 

32

 

450

 

124

 

121

 

 

 

 

 

 

 

 

 

Rapid

 

3.0

 

80

 

50

 

1050

 

218

 

214

Ultra Rapid

4.2

100

63

1600

305

300

26

Page 8
Image 8
Smeg PX140NL, PX140BE, PX140D manual Adjusting for bottled gas, Rated BurnerheatBottled gas G30/G31 30/37 mbar capacity