Instructions for the Installer

5.3 Adjusting for natural gas

The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar. To return the appliance to the condition required to use this type of gas, proceed as described in point “ 5.2 Adjusting for bottled gas” but select the nozzles and adjust the primary air flow for natural gas, as indicated in the table below and in point “ 5.4 Adjusting the primary air flow”.

 

Burner

 

Rated heat

 

Natural gas - G20 20 mbar

 

 

 

Capacity (kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

Reduced heat capacity

 

 

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

 

 

 

Auxiliary

 

1.05

 

73

 

400

 

 

 

 

 

 

 

 

 

Semi rapid

 

1.7

 

92

 

450

 

 

 

 

 

 

 

 

 

Rapid

 

3.0

 

123

 

1050

 

 

 

 

 

 

 

 

 

Ultra Rapid

 

4.2

 

150

 

1400

 

5.4 Adjusting the primary air flow

Refers to the gap “X” in mm.

 

BURNER

 

G20

 

G30/G31

 

 

20 mbar

 

30/37 mbar

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

0.5

 

3

 

 

 

 

 

Semi rapid

 

0.5

 

2

 

 

 

 

 

Rapid

 

2

 

3.5

 

 

 

 

 

 

Ultra Rapid

 

4

 

open

 

 

 

 

 

 

To identify the burners on your hob, refer to the drawings in point “ 5.8 Hob burner layout”.

27

Page 9
Image 9
Smeg PX140BE, PX140NL, PX140D manual Adjusting for natural gas, Adjusting the primary air flow