Instructions for the installer

Instructions for the installer

2. INSTALLATION

2.1 Electrical connection

Check that the mains voltage and power cable ratings are as per the information provided on the label attached to the oven door frame.

This label must never be removed.

It is obligatory for the electrical system to be earthed according to the methods required by safety rules.

If a plug and socket connection is being used make sure that the plug and socket are compatible. Avoid use of adapters and shunts as these could cause overheating and risk of burns.

If a fixed connection is being used fit cable line with an omnipolar circuit breaker with a contact opening gap equal to or greater than 3 mm in an easily accessible position in proximity to the oven.

For operation on 220-240V : use an
H05RR-F / H05RN-F type three-core cable (3 x 1.5 mm2).

The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer.

2.1.1 Ovens with hob controls

In the ovens with hob controls the power cable is not supplied. Use a H05RR-F or H05RN-F rubber-sheathed cable making sure that it does not come into contact with any external metal parts of the oven when routing.

Remove rear cover by loosening relevant screws to gain access to the terminal strip. If necessary change jumper configuration as shown in the diagram and then connect wires making sure that the earth wire is at least 20 mm longer than the others. Secure power cable to oven by means of an appropriate fitting.

30

Page 4
Image 4