Smeg SC06MFX cable of 3 x 4 mm2, cable of 4 x 2.5 mm2, cable of 5 x 1.5 mm2, Positioning the oven

Models: SC04MFX SC06MFX SC08MFX

1 33
Download 33 pages 22.7 Kb
Page 31
Image 31
(cable of 3 x 4 mm2).

Instructions for the installer

Operation at 220-240 V~: use a H05RR-F /H05RN-Fthree-wire cable

(cable of 3 x 4 mm2).

Operation at 380-415V2N~: use a type H05RR-F /H05RN-Ffour-wire cable

(cable of 4 x 2.5 mm2).

Operation at 380-415V3N~: use a type H05RR-F /H05RN-Ffive-wire cable

(cable of 5 x 1.5 mm2).

The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.

14.2 Positioning the oven

The appliance is designed for building-in to cabinets made from any heat- resistant material. Comply with the dimensions shown in figures 1, 2, and 3. When installing under worktops, comply with the dimensions shown in figure 1-3. When installing under worktops incorporating combined hobs, a gap of at least 110 mm must be left from any side wall, as shown in figure 1. When installing in tall units, comply with the dimensions shown in figure 1-2, bearing in mind that the top/rear of the unit must have an opening 80- 90 mm deep. Screw the 4 screws A into the inside of the frame (fig. 1). For installation under counter-top hobs, make sure that the rear/bottom of the unit has an opening similar to that shown in figure 1 (ref. B). See the instructions supplied with the hob for the relative positioning and fixing procedures.