Instructions for the Installer
Operation at 380-415V 3N~: use a H05RR-F / H05RN-F five-wire cable (cable of 5 x 2.5 mm2).
Operation at 380-415V 2N~: use a H05RR-F four-wire cable (cable of 4 x 4 mm2).
Operation at 220-240 V~: use a H05RR-F three-wire cable (cable of 3 x 6 mm2).
The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.
The power supply cable must be fitted with a suitable five-pin plug (see technical data plate) or, for appliances operating on 220-240 V, a three-pin plug. The power supply plug and wall socket must be of the same type and compliant with the relevant regulations. Check that the appliance is earthed appropriately. Before putting the appliance into operation, check that the power supply line is properly earthed. The use of adapters or junctions is not recommended.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR INJURY OR DAMAGE CAUSED BY FAILURE TO COMPLY WITH THE ABOVE REGULATIONS