Instructions for the installer

5.2 Regulation for LPG

Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. The screwing torque of the nozzle should never exceed 3 Nm. Reposition support B so that nozzle C is covered perfectly.

Move the Venturi tube D to regulate the air flow until distance "X" is reached indicated in the chart in paragraph "5.4 Regulation of primary air” and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

Rated

BurnerheatingLPG – G30/G31 28/37 mbar capacity

(kW)

 

 

 

 

Nozzle

 

 

 

 

 

diameter

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

Auxiliary (1)

 

1.05

 

48

 

 

 

 

 

 

 

Semi-rapid (2)

 

1.65

 

62

 

 

 

 

 

 

 

Rapid (3)

 

2.55

 

76

 

 

 

 

 

 

Rapid (4)

 

3.1

 

85

 

 

 

 

 

 

Ultra rapid (5)

 

3.9

 

95

 

By-pass

 

Reduced

 

mm

 

flowrate

 

1/100

 

(W)

 

 

 

 

 

30

 

 

 

33 (*)

 

380

 

 

 

 

 

30

 

 

 

33 (*)

 

380

37

40 (*)

650

43

45 (*)

750

 

65

1600

 

Flowrate

 

Flowrate

 

 

 

 

 

g/h G30

 

g/h G31

 

 

 

 

 

 

 

 

 

 

 

76

75

120

118

185

182

225

222

283

279

(*) By-pass value for valveless appliances.