Instructions for the installer

5.3 Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.2 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph "5.4 Regulation of primary air”. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

 

 

Rated

 

 

 

 

 

 

Burner

 

heating

 

Natural gas – G20 20 mbar

 

 

 

capacity

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

 

Reduced flowrate

 

 

 

 

 

1/100 mm

 

 

(W)

 

 

 

 

 

 

 

 

Auxiliary (1)

 

1.05

 

73

 

 

380

 

 

 

 

 

 

 

Semi-rapid (2)

 

1.65

 

92

 

 

380

 

 

 

 

 

 

 

Rapid (3)

 

2.55

 

115

 

 

650

 

 

 

 

 

 

 

Rapid (4)

 

3.1

 

126

 

 

750

 

 

 

 

 

 

 

Ultra rapid (5)

 

3.9

 

140

 

 

1400

 

5.4Regulation of primary air

Referred to distance “X” in mm.

BURNER

 

G20

 

 

 

20 mbar

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

2.0

 

 

 

 

 

Semi-rapid (2)

 

1.5

 

 

 

 

Rapid (3)

 

2.0

 

 

 

 

Rapid (4)

 

2.5

 

 

 

 

Ultra rapid (5)

 

2.0

 

G30/G31

28/37 mbar

2.0

1.5

5.0

10.0

4.0

To identify the burners on your hob, refer to the drawings in point “6.3 Arrangement of burners on hob “