I N T E G R AT E D INSTALLATION SPECIFICATIONS
ACCESSORIES
Optional acces- sories are available through your
P LU M B I N G REQUIREMENTS
For Integrated models with an automatic ice maker, rough in the water supply line. Connect the 6,35 mm water line from the ice maker water valve to the copper water supply. Use an easily accessible
The Installation illustrations on pages
The line must be routed around the
mmof excess water line to remain outside the wall or floor for easy connection to the unit.
IMPORTANT NOTE: Do not route the water supply line in front of the compressor tray. The tray must be slid forward for service.
A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 1.4 bar to
6.9 bar.
A reverse osmosis system can be used, provided there is a consistent water pressure of 1.4 bar to 6.9 bar supplied to the water valve at all times.
IMPORTANT NOTE: In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently.
10