Sub-Zero ICB700TCI, ICB700TFI Wood Floor Applications, Concrete Floor Applications, Dimension A

Models: ICB700TR ICB700TCI ICB700TFI

1 104
Download 104 pages 47.94 Kb
Page 13
Image 13
WOOD FLOOR APPLICATIONS

I N T E G R AT E D INSTALLATION INSTRUCTIONS

A N T I - T I P B R AC K E T I N S TA L L AT I O N

 

 

 

 

WOOD FLOOR APPLICATIONS

CONCRETE FLOOR APPLICATIONS

Use the six #12 x 63,5 mm wood screws and

Use the two #10 x 95,25 mm concrete wedge

the six #12 flat washers provided. Drill pilot

anchors, two #12 x 63,5 mm wood screws and

holes 5 mm diameter maximum, and be sure

two #12 flat washers provided. Be sure that the

that the screws penetrate through the flooring

anchors and screws hold tight. Refer to

material and into the wall plate a minimum of

illustration 2 below.

19 mm. Be sure that the screws hold tight.

IMPORTANT NOTE: In some installations the

Refer to illustration 1 below.

subflooring or finished floor may require

 

 

angling the wood screws used to fasten the

 

anti-tip bracket to the back wall. Refer to

 

illustrations 1 and 2.

 

 

 

 

 

 

 

 

 

 

Make sure that there are no electrical

 

 

wires or plumbing in the area which the

 

 

screws could penetrate.

 

 

 

 

 

 

Finished Flooring

Underlayment

Wall Plate

Subflooring

WOOD FLOOR

Illus. 1

Finished Flooring

 

Underlayment

 

Wall Plate

 

Subflooring

38

 

mm

CONCRETE

min

FLOOR

 

Illus. 2

S P E C I F I C A T I O N S

 

Dimension A

 

686 mm Wide Units

343 mm

914 mm Wide Units

457 mm

13

Page 13
Image 13
Sub-Zero ICB700TCI, ICB700TFI, ICB700TR Wood Floor Applications, Concrete Floor Applications, Dimension A