DOOR PANEL INSTALLATION

I N T E G R AT E D INSTALLATION INSTRUCTIONS

PA N E L I N S TA L L AT I O N

If you have questions, contact your Sub-Zero

dealer or cabinet supplier. Additional panel

information can be found in the Sub-Zero

Design Guide.

DOOR PANEL INSTALLATION

Remove the two pieces of mounting hardware

attached to the front of the door and set aside.

Place the door panel lying face down on a

protected surface to ensure that the front is not

PANEL BRACKET POSITIONING

606 mm* FOR 686 mm WIDE UNITS

 

835 mm* FOR 914 mm WIDE UNITS

37 mm*

 

1153

scratched or damaged.

mm*

Position the plastic template provided flush with the lower edge of the door. Be sure you are following the exact location for the right- hand (RH) or left-hand (LH) door position. Refer to illustration 12 on page 18.

 

135

IMPORTANT NOTE: The template has two

mm

 

usable sides, one side for the door and one for

 

 

 

 

the drawers. Make sure you use the proper

 

 

holes and side. Remember you are viewing the

287

door panel from the back side in illustration 12

mm

 

 

on page 18.

 

 

 

 

 

 

 

RH DOOR SWING

LH DOOR SWING

132 mm

32

mm

345 mm

570 mm

Once you have located the proper position for the bracket, mark the pilot holes, remove the template and drill pilot holes for mounting the bracket. It is best to start with a few holes, position the bracket, drill the remaining pilot holes and then secure the mounting bracket with the #8 x 12,7 mm screws provided. Illus- tration 13 shows the mounting hardware location for door and drawer panels.

 

32

 

 

 

214

mm

 

 

 

 

 

424

mm

 

 

 

mm*

 

 

 

 

 

 

 

 

 

 

606 mm* FOR 686 mm WIDE UNITS 679 mm* FOR 686 mm WIDE UNITS 835 mm* FOR 914 mm WIDE UNITSRH DOOR SWING 908 mm* FOR 914 mm WIDE UNITS LH DOOR SWING

VIEW FROM BACK OF PANELS

*DIMENSIONS MAY VARY

IMPORTANT NOTE: Dimensions in illustration

13 are based on a 3 mm reveal. A reveal of up to 6 mm is possible, but panel dimensions need to be adjusted accordingly.

Exercise caution when drilling holes for mounting hardware. This is especially critical with inset panels.