6.2.4 Troubleshooting Built-in Filtration System

PUMP RUNS BUT DOES

PUMP RETURNS OIL TO

NOT RETURN OIL TO

FRYPOT VERY

FRYPOT.

SLOWLY.

Verify that filter pan is properly

seated in filter base, and that the oil return hose is not kinked or twisted.

Resume filtering.

Is oil

returning to Yes Problem resolved. frypot?

No

Verify that filter pan O-ring is

present and in good condition, and that recessed area in filter base is unobstructed. Resume filtering.

Check to see if filter paper (or pad) is heavily coated with crumbs. If so replace paper (or pad). Also verify the filter paper (or pad) is on top of the filter screen, not below it. Resume filtering.

Is oil

returning Yes Problem resolved. correctly?

No

Verify that filter pan is properly

seated in filter base, and that the oil return hose is not kinked or twisted.

Resume filtering.

Is oil

Yes

Problem resolved.

Is oil

Yes

Problem resolved.

returning to

returning

frypot?

 

 

correctly?

 

 

No

 

 

No

 

 

Probable cause is

 

 

Probable cause is

 

 

obstruction in tube on

 

 

obstruction in tube on

 

 

bottom of base.

 

 

bottom of base.

 

 

6-7

Page 46
Image 46
Frymaster H52 Series warranty Troubleshooting Built-in Filtration System