WARNING

“Dry-firing” your unit will cause damage to the frypot. Always ensure that melted shortening, cooking oil, or water and boil-out solution is in the frypot before firing your unit for any extended period.

4.It is suggested that the burner manifold pressure be checked at this time by the local gas com- pany or an authorized service agent. Refer to “Check Burner Manifold Pressure” in Chapter 5 of this manual for the proper procedure. The accompanying tables list the burner manifold gas pressures for the various gas types that can be used with this equipment.

CE Standard

Burner Manifold Gas Pressures

for Fryers Manufactured After April 1999

 

Pressure (mbar)

 

 

 

 

Single

Dual

Gas

Vat

Vat

Natural Gas Lacq

7

7

(G20) under 20 mbar

 

 

Natural Gas Groningue *

10

10

(G25) under 25 mbar

 

 

Natural Gas Groningue

10

10

(G25) under 20 mbar

 

 

Butane

17

17

(G30) at 28/30 or 50 mbar

 

 

Propane

20

20

(G31) under 37 or 50 mbar

 

 

CE Standard

Burner Manifold Gas Pressures

for Fryers Manufactured Through April 1999

 

Pressure (mbar)

 

 

 

 

Single

Dual

Gas

Vat

Vat

Natural Gas Lacq

7

6,5

(G20) under 20 mbar

 

 

Natural Gas Gronigue *

10

9

(G25) under 25 mbar

 

 

Natural Gas Gronigue

10

9

(G25) under 20 mbar

 

 

Butane

17

16,5

(G30) at 28/30 or 50 mbar

 

 

Propane

20,2

18,5

(G31) under 37 or 50 mbar

 

 

* Belgian G25 = 7,0 mbar (single or dual)

* Belgian G25 = 7,0 mbar (single) or 6,5 (dual)

Non-CE Standard

Burner Manifold Gas Pressures

Gas

Pressure

Natural

3" W.C.

0.73 kPa

 

Propane

8.25" W.C.

2.5 kPa

 

 

 

 

 

5.Check the programmed temperature or analog controller thermostat setting. (Refer to Chapter 3, Operating Instructions, for the setpoint programming instructions for your particular controller.)

2.5Converting to Another Gas Type

Your fryer is configured at the factory for either natural gas or propane (LP) gas. If you desire to switch from one type of gas to another, a gas conversion kit must be installed by a Factory Authorized Service Center technician.

DANGER

Switching to a different type of gas without installing the proper conversion kit may result in fire or explosion! NEVER attach your fryer to a gas supply for which it is not configured.

2-7

Page 12
Image 12
Frymaster H52 Series warranty Converting to Another Gas Type, Gas Vat