WARNING
4.It is suggested that the burner manifold pressure be checked at this time by the local gas com- pany or an authorized service agent. Refer to “Check Burner Manifold Pressure” in Chapter 5 of this manual for the proper procedure. The accompanying tables list the burner manifold gas pressures for the various gas types that can be used with this equipment.
CE Standard
Burner Manifold Gas Pressures
for Fryers Manufactured After April 1999
| Pressure (mbar) | ||
|
|
| |
| Single | Dual | |
Gas | Vat | Vat | |
Natural Gas Lacq | 7 | 7 | |
(G20) under 20 mbar | |||
|
| ||
Natural Gas Groningue * | 10 | 10 | |
(G25) under 25 mbar | |||
|
| ||
Natural Gas Groningue | 10 | 10 | |
(G25) under 20 mbar | |||
|
| ||
Butane | 17 | 17 | |
(G30) at 28/30 or 50 mbar | |||
|
| ||
Propane | 20 | 20 | |
(G31) under 37 or 50 mbar | |||
|
|
CE Standard
Burner Manifold Gas Pressures
for Fryers Manufactured Through April 1999
| Pressure (mbar) | ||
|
|
| |
| Single | Dual | |
Gas | Vat | Vat | |
Natural Gas Lacq | 7 | 6,5 | |
(G20) under 20 mbar | |||
|
| ||
Natural Gas Gronigue * | 10 | 9 | |
(G25) under 25 mbar | |||
|
| ||
Natural Gas Gronigue | 10 | 9 | |
(G25) under 20 mbar | |||
|
| ||
Butane | 17 | 16,5 | |
(G30) at 28/30 or 50 mbar | |||
|
| ||
Propane | 20,2 | 18,5 | |
(G31) under 37 or 50 mbar | |||
|
|
* Belgian G25 = 7,0 mbar (single or dual)
* Belgian G25 = 7,0 mbar (single) or 6,5 (dual)
Burner Manifold Gas Pressures
Gas | Pressure | |
Natural | 3" W.C. | |
0.73 kPa | ||
| ||
Propane | 8.25" W.C. | |
2.5 kPa | ||
| ||
|
| |
|
|
5.Check the programmed temperature or analog controller thermostat setting. (Refer to Chapter 3, Operating Instructions, for the setpoint programming instructions for your particular controller.)
2.5Converting to Another Gas Type
Your fryer is configured at the factory for either natural gas or propane (LP) gas. If you desire to switch from one type of gas to another, a gas conversion kit must be installed by a Factory Authorized Service Center technician.
DANGER
Switching to a different type of gas without installing the proper conversion kit may result in fire or explosion! NEVER attach your fryer to a gas supply for which it is not configured.