DISPLAY SHOWS

IGNITION FAILURE,

ALARM IS SOUNDING,

AND BURNERS WILL

NOT LIGHT

Verify that all drain

valves are fully

closed, the main gas valve is open and the gas valves on the fryer are on.

Press ON/OFF switch

OFF (on Split Vat

units, both switches must be OFF). Press ON/OFF switch ON.

Is fryer

operating Yes Problem resolved. correctly?

No

Probable causes are a

defective or misaligned drain

safety switch or an open

high-limit thermostat.

Call FASC.

DISPLAY SHOWS

IGNITION FAILURE,

ALARM IS SOUNDING,

BUT BURNERS LIGHT

Press ON/OFF switch OFF

(on Split Vat units, both switches must be OFF).

Swap computer with another

known to be working

correctly. Press ON/OFF

switch ON.

 

 

False alarm. Install

 

 

computer on another

Is fryer

 

fryer and test operation.

Yes

If problem repeats,

operating

computer is defective and

correctly?

 

must be replaced. If not,

 

 

problem should be

 

 

investigated by

No

 

FASC.

 

 

Probable cause is a

defective ignition module.

Call FASC.

6-3

Page 42
Image 42
Frymaster H52 Series warranty Ignition Failure