BURNERS DO NOT

LIGHT

(POWER LIGHT ON,

HEAT LIGHT ON,

TROUBLE LIGHT ON)

Verify that all drain valves are fully closed. Verify the main gas valve is open and the gas valve knob (non- CE units) is ON. Place power swtiches in OFF position, then back ON.

Did burners

Yes

Problem resolved.

light?

 

 

No

Place power switches in OFF

position. Disconnect and reconnect the flexible gas line quick-disconnect fitting. Place power switches in ON position.

Did burners

Yes

Problem resolved.

light?

 

 

No

Place power switches in OFF

position. Verify that combustion air blower inlet is open and that blower is clean. Place power switches in ON position.

No

 

 

Did burners

Yes

Problem resolved.

light?

 

 

No

Problem is beyond scope of operator troubleshooting. Call

FASC

6-6

FRYER FAILS 2ND

HIGH-LIMIT TEST

(HEAT LIGHT ON, 2ND HI-LIMIT LIGHT OFF, AND FRYER CONTINUES TO HEAT IN 2ND HI-LIMIT TEST POSITION.)

Probable cause is a defective high-

limit thermostat. Call FASC.

Page 45
Image 45
Frymaster H52 Series warranty Did burners