Frymaster H52 Series warranty Troubleshooting Fryers Equipped with Analog Controllers

Models: H52 Series

1 48
Download 48 pages 48.78 Kb
Page 44
Image 44
6.2.3 Troubleshooting Fryers Equipped with Analog Controllers

6.2.3 Troubleshooting Fryers Equipped with Analog Controllers

FRYER OPERATES

PROPERLY BUT "POPS" WHEN BURNERS LIGHT.

Place power switches in OFF

position. Verify that combustion air

blower shutter is open and that blower is clean. Place power switches in ON position.

POWER LIGHT ON,

TROUBLE LIGHT ON,

HEAT LIGHT OFF,

BURNERS DO NOT

LIGHT.

Place power switches in OFF position. Swap controller with another known to be working. Place power switches ON.

Did popping

Yes

Problem resolved.

cease?

 

 

No

Problem is beyond scope of operator troubleshooting. Call

FASC

POWER SWITCH ON,

BUT NO CONTROLLER

LIGHTS ARE LIT.

Verify that power cord is plugged into live circuit, fryer circuit breaker is not tripped, and hood circuit breaker is not tripped..

If above conditions are correct,

Does

fryer operate Yes Manual background correctly?

No

Probable causes are loose or broken wiring connections.

Call FASC.

FRYER IS OPERATING

NORMALLY, BUT

RECOVERY IS SLOW

WHEN COOKING.

Place power switches in OFF

position. Verify that combustion air blower shutter is properly adjusted and that blower is clean. Place power switches in ON position.

Defective controller.

Replace.

probable causes are failed

transformer or failed controller. Call

FASC.

Is recovery

Yes

Problem resolved.

time correct?

 

 

No

Probable cause is low or fluctuating

gas pressure. Call FASC.

6-5

Page 44
Image 44