4.Press the switch to save the settings.

5.Press either ON/OFF switch to save the setting and exit the setup mode. Both displays will change to OFF.

How to Configure the Computer for Use on Either a Full-Vat or a Split-Vat Fryer

1.Enter the setup mode. See How to Enter the Setup Mode on Page 3-8.

2.Press and release the switch until 1 vat appears in the left display.

3.Press the right 1 or 2 switch to toggle back and forth between full-vat (yes) or split-vat (NO).

4.Press the switch to save the settings.

5.Press either ON/OFF switch to exit the setup mode. Both displays will change to OFF.

How to Change Computer Product/Temperature Displays

1.Enter the setup mode. See How to Enter the Setup Mode on Page 3-8.

2.Press and release the switch until the word DISPLAY appears in the left display.

3.Press the right 1 or 2 switch to toggle back and forth between constant product display (CONSTANT) or alternating temperature and product display (ALT).

4.Press the switch to save the settings.

5.Press either ON/OFF switch to exit the setup mode. Both displays will change to OFF.

How to Calibrate Computer Temperature to Actual Frypot Temperature

NOTE: For this procedure, actual frypot temperature refers to the temperature of the oil in the frypot as measured with a good-grade thermometer or pyrometer. The computer’s temperature can only be adjusted ±5°F (±3°C). The computer cannot be adjusted to a temperature greater than 375°F (191°C).

1.Enter the setup mode. See How to Enter the Setup Mode on Page 3-8.

2.Press and release the switch until CALIB appears in the display.

3.Press the temperature check switch . The frypot temperature sensed by the computer will be displayed. In split-vat units, the temperatures for each side will be displayed.

4.For the left side of a split-vat: Press the left Fahrenheit or 3 for Celsius). Press the left 2 Fahrenheit or 3 for Celsius).

1switch to go UP a degree (maximum of 5 for switch to go DOWN a degree (maximum of 5 for

3–9

Page 22
Image 22
Frymaster H52 Series warranty How to Change Computer Product/Temperature Displays