Frymaster H52 Series warranty Open Drain Valve Indication, Low Temperature Indication

Models: H52 Series

1 48
Download 48 pages 48.78 Kb
Page 19
Image 19
Open Drain Valve Indication

Open Drain Valve Indication

If, when the ON/OFF Low Temperature Indication switch is pressed to the ON position, the display reads IGNITION FAILURE, verify that the drain valve is fully closed. A drain safety switch built into the drain valve assembly prevents the coil of the gas valve(s) from being energized if the drain valve is not completely closed. After verifying that the valve is fully closed, turn the computer OFF* for at least 5 seconds, then turn it back on. If the message reappears, there is a problem in the electrical circuitry of the fryer or the computer. Contact your Frymaster Factory Authorized Service Center (FASC).

*On early-version M-100B split-vat units, BOTH computers must be turned off, even though the problem condition may be associated with only one vat.

Low Temperature Indication

If the frypot temperature drops to more than 45°F (25°C) below the programmed setpoint temperature during the cooking cycle, the cook switches will lock, the display will flash lOW TEMP and an

audible alarm will sound. If the frypot temperature returns to a range between 45°F (25°C) to 15°F (8°C) of setpoint, the audible alarm will stop, but the cook switches remain locked and the display

3–6

Page 19
Image 19
Frymaster H52 Series warranty Open Drain Valve Indication, Low Temperature Indication