16.ADAPTATION TO DIFFERENT TYPES OF GAS

Instructions for the installer

16.ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the appliance from the mains.

The hob of the cooker is adjusted for use with either natural gas at a pressure of 1.0kPa. If used with other types of gas, you have to replace the nozzles, then adjust the minimum flame on the gas taps. For nozzle replacement and burner adjustment operate as described in the following paragraph.

16.1 Replacement of nozzles on the hob

This operation requires no primary air regulation.

1Extract the grids and remove all the caps and flame-spreader crowns;

2Unscrew the burner nozzles with a 7 mm socket wrench;

3Replace the nozzles according to the type of gas to be used and the description in paragraph "16.2 Burner and nozzle characteristics table ";

4Replace the burners in the correct position.