CHECK / LUBRICATE FREE-HAND LINKAGE

Regular Maintenance

CHECK / LUBRICATE FREE-HAND LINKAGE

Check the function of the Free-Hand controls: the con- trols should function as described in the CONTROLS section. It is critical for the safe operation of the unit that the controls disengage when released.

Lubricate as shown in figure 13.

IMPORTANT NOTE

If the controls do not function properly, lubricate them. If lubrication does not rectify the problem, see your dealer. Under no circumstances should the unit be used if the controls are not functioning properly.

Figure 13. Lubricate Free Hand Control

IMPORTANT NOTE

It is very important that grease fittings on the auger shaft are lubricated regularly. If auger rusts to shaft, damage to worm gear may occur if shear pins do not break.

LUBRICATING THE AUGER SHAFT & ASSEMBLY

1.Remove cotter pin (C, Figure 14) and shear pin (B).

2.Use a grease gun and squirt several shots of grease into grease fitting (A).

3.Rotate auger assembly (D) several times to distribute the grease evenly. Repeat step 2.

4.Reinstall shear pin (B) and cotter pin (C).

5.Repeat procedure for other side.

C

B

A

B

C

A

D

D

Figure 14. Lubricating the Auger Shaft Assembly

A.

Grease Fittings

C. Cotter Pins

B.

Shear Pins

D. Auger Assembly