Counting Scale 9222
4. WEIGHING AND COUNTING
■Zero setting
0 | If after powering up the scales there is | |||
no load on the scales but the display is | ||||
| ||||
| not zero, press | 0 | . Possible zero setting | |
|
|
| ||
| range | |||
| The display shows | . |
■Calculating / Deducting
the Tare Weight
Weighing with the tare weight calculated
•Place the container on the platform.
•Press .
The display goes to zero.
The display shows .
Weighing with the tare weight manually entered
•Enter the known tare weight in grams.
• Press until the value in the display flashes.
•Place the container on the platform.
•Place the items to be weighed on
the scales.
The net weight is displayed when the scales come
to rest. The display shows .
Deleting the Tare Weight
When the scales are unladen press .
■Counting
Counting with an unknown unit weight (method 1)
•Place the counted reference unit total on the platform.
•Enter the unit total and press within 4 seconds to calculate the
unit weight, otherwise the input will be deleted automatically.
Other amounts placed on the scales will now also be counted.
Counting with an unknown unit weight (method 2)
•When the scales are unladen press . "SAMPLE" appears in the sec- ond line of the display and "100"
in the third line.
•Enter the unit total.
•Place the counted reference unit total on the platform.
•Wait briefly until the scales have
calculated the unit weight.
Other amounts placed on the scales will now also be counted.
Counting with an unknown unit weight (method 3)
•Place the counted reference unit total on the platform.
•Press . "SAMPLE" appears in the second line of the display and "100"
in the third line.
•Enter the unit total.
8