TROUBLESHOOTING

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSES

SOLUTIONS

 

 

 

The Air Conditioner will not start

The air conditioner is unplugged

Make sure the air conditioner is

 

 

plug is pushed completely into the

 

 

outlet

The fuse is blown/circuit breaker is tripped.

Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.

Power Failure

The unit will automatically re-start

 

when power is restored.

 

There is a protective time delay

 

(approx. 3 minutes) to prevent

 

tripping of the compressor

 

overload. For this reason, the unit

 

may not start normal cooling for 3

 

minutes after it is turned back on.

The current interrupter device is tripped.

Press the RESET button located on the power cord plug.

If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

The Air Conditioner does not cool

Airflow is restricted

Make sure there are no curtains,

as it should

 

blinds, or furniture blocking the

 

 

front of the air conditioner

 

 

 

 

The temperature control may not be

Lower the set thermostat tempera-

 

set correctly.

ture

 

 

 

 

The air filter is dirty

Clean the filter. See the Cleaning

 

 

and Care Section of the manual.

 

 

 

 

The room may be too warm

Please allow time for the room to

 

 

cool down after turning on the air

 

 

conditioner.

 

 

 

 

Cold air is escaping

Check for open furnace registers

 

 

and cold air returns

 

 

 

 

The Cooling Coils are frozen

See “Air Conditioner Freezing Up”

 

 

below.

The Air Conditioner is freezing up

Ice blocks the air flow and stops the air

Set the MODE dial to HIGH FAN

 

conditioner from cooling the room

or HIGH COOL and set the ther-

 

 

mostat to a higher temperature

 

The batteries are inserted incorrectly

 

The Remote Control is not working

Check the position of the batteries.

 

The batteries may be dead

Replace the batteries

 

 

 

21

Page 21
Image 21
Soleus Air GM-CAC-10SE manual Troubleshooting, Problem, Possible Causes, Solutions, The Air Conditioner will not start