Soleus Air PH5(S) SERIES Parts & Assembly, Assembly & Installation, Exhaust Hose, Window Kit

Models: PH5(S) SERIES

1 16
Download 16 pages 41.63 Kb
Page 6
Image 6
PARTS & ASSEMBLY

PARTS & ASSEMBLY

PARTS

EXHAUST HOSE

WINDOW KIT

HOSE ADAPTER

EXHAUST HOSE

WINDOW KIT

ADAPTER

WINDOW KIT

ASSEMBLY & INSTALLATION

INSTALLATION

When the unit is operating as an air conditioner, heater, or dehumidifier, the unit draws in fresh outdoor air and exhausts hot air (or cold air in heat mode) out of the room to complete the air exchange. When the unit is operating in fan mode, no outdoor air exchange takes place. The window kit and exhaust hose do not need to be installed when the unit is used as a fan.

NOTE: The supplied window kit can be installed in sliding windows and sliding glass doors up to 8 ft. long (approximate length).

MOUNTING THE EXHAUST HOSE

Choose a suitable location, near a grounded electrical outlet and suitable window or door. Remove packaging and locate components.

Extend both ends of the exhaust hose approximately 6 inches.

Screw the window kit adapter onto one end of the exhaust hose clockwise. Screw the hose adapter onto the other end of the exhaust hose clockwise.

Remove the outlet cover from the back of the unit by screwing them counter-clockwise, then lifting up.

Mount the exhaust hose onto the back of the unit by locking the hose adapter into place.