ELECTRICAL REQUIREMENTS

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove the ground prong. Do not use an adapter

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock

Recommended Ground Method

The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front).

Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord.

Wiring Requirements

Power Supply Cord

 

 

115 volt (103.5 min.—126.5 max)

0-12 amps

15-amp time-delay fuse or circuit breaker

Use on single outlet circuit only

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the cus- tomer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.

It is the customer’s responsibility:

To contact a qualified electrician

To assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.

Copies of the standards listed may be obtained from: National Fire Protection Association

One Batterymarch Park

Quincy, Massachusetts 02269

LCDI Power Cord and Plug

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.

The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de- energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:

1.Plug power cord into a wall outlet

2.Press the TEST Button, the circuit should trip and cut all power to the air conditioner

3.Press the RESET button for use

If a test is performed and the indicator light remains ON, the current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Customer Service for troubleshooting recommendations.

3

Page 4
Image 4
Soleus Air SG-WAC-10ESE manual Electrical Requirements, Recommended Ground Method, It is the customer’s responsibility

SG-WAC-12ESE, SG-WAC-10ESE specifications

The Soleus Air SG-WAC-10ESE and SG-WAC-12ESE are portable air conditioners designed to provide effective cooling solutions for small to medium-sized spaces. Both units blend efficiency, convenience, and versatility to create an appealing option for homeowners and renters alike.

One of the main features of the Soleus Air SG-WAC-10ESE and SG-WAC-12ESE is their energy-efficient design. Both units are equipped with a high-efficiency compressor that significantly reduces energy consumption while delivering superior cooling performance. The Energy Efficiency Ratio (EER) ratings for these models highlight their ability to cool effectively without unnecessary energy usage. This translates into lower electricity bills and a reduced environmental footprint.

These air conditioners come with a range of operating modes, including cooling, dehumidifying, and fan-only settings. This versatility allows users to customize their indoor environment based on their specific needs. The dehumidifying function is particularly beneficial in humid climates, as it helps to reduce moisture levels, providing additional comfort and preventing mold growth.

The Soleus Air SG-WAC-10ESE and SG-WAC-12ESE are also designed with user convenience in mind. The units feature an easy-to-use LED display and remote control, offering an intuitive interface for adjusting settings from across the room. Additionally, the programmable 24-hour timer allows users to set the air conditioner to operate only when needed, enhancing energy savings.

Portability is another key characteristic of these models. Both units come with caster wheels and built-in handles, making it easy to move them from room to room as needed. This feature is particularly useful for those who want to cool different areas of their home throughout the day.

Noise levels are minimized in the Soleus Air SG-WAC-10ESE and SG-WAC-12ESE, making them suitable for bedrooms and living areas. The air conditioners employ a whisper-quiet operation that maintains a peaceful environment while providing effective cooling.

In terms of installation, these window units come with a comprehensive installation kit, ensuring a hassle-free setup process. Their sleek design fits well with various interior styles, allowing them to blend seamlessly into any space.

In summary, the Soleus Air SG-WAC-10ESE and SG-WAC-12ESE are efficient and user-friendly air conditioning solutions that prioritize comfort, convenience, and energy savings. With their range of features and technologies, they are well-suited for meeting the cooling needs of diverse living environments.