INSTALLATION & ASSEMBLY INSTRUCTIONS

INSTALLATION & ASSEMBLY INSTRUCTIONS

Window Preparation

Please read all instructions prior to installing your air conditioner. Two people are recommended to install this product. If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing the unit.

Before installing the unit, check the dimensions of your window to make sure the air conditioner will fit. This unit is made to fit inside a standard double-hung window. Make sure the window is in good shape and able to firmly hold the needed screws. If not, make repairs prior to installing the unit.

Model

SG-WAC-15ESE-C

SG-WAC-18ESE_C

Unit Height

17 5/8”

17 5/8”

Unit Width

23 1/2”

23 1/2”

Min. Window Opening (See

18 1/2”

18 1/2”

FIG 1)

 

 

Min. Window Width

26 1/2”

26 1/2”

Max Window Width

40 1/2”

40 1/2”

 

 

 

Storm Window Requirements

A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly. To adjust for this, attach a board or piece of wood to the sill. The board or wood piece should have a depth of at least 1 1/2”. Make sure the board or piece of wood is approximately 1/2” higher than the storm window frame. This will allow the air conditioner to tilt enough for proper drainage. (See FIG. 2).

FIG. 1

SASH

Storm window frame or obstruction

FIG. 2

Storm window frame or obstruction

SASH

Board or wood piece must be approximately 1/2” higher than the storm window frame for proper drainage

Prior to Installing the Air Conditioner

1.Check for anything that could block airflow. Check the area outside of the window for things such as shrubs, trees, or awnings. Check the inside area to make sure curtains, drapes, or blinds will not prevent proper airflow.

2.Check the available electrical outlet. The power supply must be the same as shown on the unit serial nameplate (located on the left side of the unit, near the front faceplate). Be sure the outlet is close enough for the power cord to reach.

3.Carefully unpack the air conditioner. Remove all packing material and make sure the floor is protected when remov- ing. Due to the large size of this air conditioner, two people should move the unit together.

When handling the unit, be careful to avoid cuts from the sharp metal edges and aluminum fins on the front and rear coils.