7. X-EQ Signal Flow

7. X-EQ Signal Flow

7.1 Serial Mode

7.2 Parallel Mode

In s erial (defau lt) filter mode, the i nput signal is init ially

When the Parallel button is engaged, the si x bell bands are

amplified or attenuated using the i nput gain slider a nd then

arranged in an alternative manner. As in serial mode, the signal

passed to the input meter. It then enters the serial filter chain,

is fed to the input stage, into the high pass filter and then onto

has processing applied, and is then passed to the output stage,

the low shelf filter. The signal is then fed to all six ba nds

again with level control and metering.

simultaneously, processed and then summed back together.

The Band Control section and Interactive EQ graph are both

Finally, again as in the serial mode, the signal is passed to the

used to control the band parameters. As the signal leaves the

high shelf filter, high pass filter and into the output stage.

filter chain, it is also fed to t he anal yser which deri ves a

 

graphical display.

 