7. X-EQ Signal Flow
7.1 Serial Mode | 7.2 Parallel Mode |
In s erial (defau lt) filter mode, the i nput signal is init ially | When the Parallel button is engaged, the si x bell bands are |
amplified or attenuated using the i nput gain slider a nd then | arranged in an alternative manner. As in serial mode, the signal |
passed to the input meter. It then enters the serial filter chain, | is fed to the input stage, into the high pass filter and then onto |
has processing applied, and is then passed to the output stage, | the low shelf filter. The signal is then fed to all six ba nds |
again with level control and metering. | simultaneously, processed and then summed back together. |
The Band Control section and Interactive EQ graph are both | Finally, again as in the serial mode, the signal is passed to the |
used to control the band parameters. As the signal leaves the | high shelf filter, high pass filter and into the output stage. |
filter chain, it is also fed to t he anal yser which deri ves a |
|
graphical display. |
|
20