Solid State Logic XR622 F.1 Introduction, F.2 F.3, Connection, Operation, X-RackMaster Module

Models: XR622

1 10
Download 10 pages 32.72 Kb
Page 3
Image 3
X-Rack Master Module

X-Rack Master Module

F.Master Module

F.1 Introduction

Used in conjunction with the XR623 X-Rack Line Return module, the XR622 X-Rack Master module provides a complete small scale mix and monitor system for studios seeking a compact solution for mixing and monitoring in the analogue domain. A single X-Rack can provide up to 28 line level inputs. Additional racks can be connected via the ‘MIX BUS LINK’ connector on the rear of the X-Rack unit, allowing additional inputs to be added to the system if required.

X-Rack units prior to serial number XRK0110 are not equipped with a ‘MIX BUS LINK’ connector.

The X-Rack Total Recall system allows session setups to be recalled instantly and can be archived as a MIDI SysEx dump to any MIDI sequencer. The monitor section controls can also be controlled remotely using MIDI controller commands from any MIDI controller. Up to three racks can be connected to an AWS 900 or AWS 900+ and integrated with the AWS 900 Total Recall system via the serial port. Connecting the MIX and REC outputs of the XR622 to the MIX and REC Insert Returns of the AWS 900 and selecting INSERT SUM mode allows almost unlimited expansion of the number of line level inputs to the console.

F.2

F.3

F.3.1

Connection

The rear panel of the module carries a pair of 25-way ‘D’ connectors. The left-hand

INS RTN

INS SND

EXT

MIX

connector provides the main and alternate Monitor outputs as well as a stereo External

ALT MON FOL MON

Input and the Mix Bus Insert Return. The right-hand connector provides Mix and

MON

REC

Record Bus outputs along with the Mix Bus Insert Send and a Follow-Monitor (pre-

 

 

level control) output.

 

 

 

 

All outputs (apart from the headphone output) operate at a nominal level of +4dBu

 

 

and are configured to drive standard line level inputs. Level compensation for feeding

 

 

600Ω inputs from the Bus, Insert and Monitor outputs is provided by removable

 

 

jumpers – refer to Section F.3.4 for details.

XR622

 

 

 

 

 

 

 

 

SEL

 

 

 

 

 

0

 

 

 

 

3

 

 

 

 

6

 

 

 

 

9

Operation

 

 

12

 

 

48

 

 

 

 

15

 

 

 

 

18

 

 

 

 

24

 

 

 

 

30

As well as a compact stereo monitor section, the X-Rack Master module contains the

MIX

36

MONITOR

mix amps and outputs for the X-Rack’s internal Mix, Record and Solo/AFL busses.

 

42

REC

1

The Mix bus is intended to be used as the main mix bus and includes a balanced

MON

 

insert point immediately before the Mix level control. The Record bus provides a

SUM

 

 

MIX LEVEL

direct path to a DAW (or any other recorder), allowing the Mix bus to be used to

 

INS

 

provide a monitor mix while recording one or more inputs via the Record bus.

 

SUM

 

If the X-Rack is fitted with XR621 Mic Amp modules these can be routed directly to

INS

 

MONITOR

the Record bus using the ‘REC L’ and ‘REC R’ switches on the XR621 module.

MIX

AFL SOLO

Mix Section 1

 

EXT

 

 

 

 

REC

 

This section carries all of the Mix bus controls; the ‘MIX LEVEL’ control allows the

ALT

LEVEL

overall gain of the Mix bus to be adjusted (the Record bus level is fixed).

 

The ‘INS’ switch brings the Mix Bus Insert Return into circuit (the Insert Send is

MONO

 

permanently active) whilst the ‘SUM REC’ and ‘INS SUM’ switches allow the

DIM

 

Record bus and Insert Return to be summed with the Mix bus to allow for summing

 

 

of additional mix sources.

CUT

 

The ‘MON’ switch enables the Mix output to be replaced with whichever source(s)

 

 

have been selected for the Monitor section.

 

 

Page F-1

Page 3
Image 3
Solid State Logic XR622 F.1 Introduction, F.2 F.3, Connection, Operation, X-RackMaster Module, F.3.1, Mix Section