Sony AA-2U Electrical Adjustments by Remote Commander, Setting the Service Adjustment Mode

Models: AA-2U

1 11
Download 11 pages 10.26 Kb
Page 2
Image 2

KV-32FV27 / 36FS13 / 36FS17 / 36FV27/ 38FS17

SECTION 4: CIRCUIT ADJUSTMENTS

ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER

Use the Remote Commander (RM-Y180, RM-Y181, RM-Y182) to perform the circuit adjustments in this section. Test Equipment Required: 1. Pattern generator 2. Frequency counter 3. Digital multimeter 4. Audio oscillator

4-1. SETTING THE SERVICE ADJUSTMENT MODE

1.Standby mode (Power off).

2.Press Display Channel 5 Sound Volume + Power

SERVICE ADJUSTMENT MODE ON

Disp. Item Item (Item) order data

VP

0

7

SERVICE

HSIZ

 

TV

 

Mode

3.The CRT displays the item being adjusted.

4.Press 1 or 2 on the Remote Commander to select the item.

5.Press 3 or 6 on the Remote Commander to change the data.

6.Press MUTING then ENTER to write into memory.

SERVICE ADJUSTMENT MODE MEMORY

4-2. MEMORY WRITE CONFIRMATION METHOD

1.After adjustment, pull out the plug from the AC outlet, then replace the plug in the AC outlet again.

2.Turn the power switch ON and set to Service Mode.

3.Call the adjusted items again to confi rm they were adjusted.

4-3. REMOTE ADJUSTMENT BUTTONS AND INDICATORS

 

MUTING

 

 

POWER

 

 

(Enter into

 

 

 

 

 

 

 

(Service Mode)

memory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISPLAY

 

 

(Service Mode)

 

 

3

 

 

 

 

 

Item (Data up)

Disp. Item Item (Item) order data

VP

0

7

SERVICE

HSIZ

 

TV

 

MUTING Green

ENTER Red

1

6

 

Disp. (Item up)

 

2

Item (Data down)

 

 

 

(Device Item Up)

5

 

 

 

 

(Device item down)

4

 

 

 

 

ENTER

 

Disp. (Item down)

 

 

(Enter into

7. Press 8 then ENTER on the Remote Commander to initialize.

Disp. Item Item (Item) order data

VP 0 7 WRITE

HSIZ TV

Carry out step 7 when adjusting IDs 0 to 7 and when replacing and adjusting IC002.

 

memory

8

 

(Initialize)

0

 

(Remove from

 

memory)

VOLUME (+)

 

(Service Mode)

 

RM-Y182

8. DO NOT turn off set until SERVICE appears.

— 15 —