2.5 Battery Charging
There is no charging circuitry in the battery pack. The
The telephone can be charged only with the battery connected the phone. This situation can be
The battery symbol is used to indicate the charging, and to indicate when the battery is fully charged. This is done using the following sequence of icons:
The uncharged segments of the battery are moving in a right to left manner until the charging stops. The sequences for each charging level is repeated until the battery is charged to that level.
When the charging sequence is finished the flashing of the battery level sign stops.
The phone shows the
2.6 Battery Safety
The battery pack contains a single
The safety concept protects against:
Over voltage: The charging is stopped when Battery Voltage (Vbat) reaches 4.25V- 4.3V. The charging resumes when Vbat falls below (4.025V - 4.125V).
Under voltage: When the cell voltage drops below 2.242V – 2.358V the cell is disconnected for discharging. Charging is still possible.
Current fuse: Finally, if all protection functions are out of order due to abnormal condition, the current fuse protects the device from explosion and fire with melting. The fuse melts 10A during 1 second.
2.7 Battery Capacity:
Standard Battery 640mAh typical
Extended Battery 920mAh typical
The phone can be charged even during making phone calls.
However, the shortest charging time will be reached when the phone is switched off.