Eclipse

When designing the housing, refer to the dimensional allowance as shown in the figure below.

˚

 

97

˚

.

82

30

.

 

21

8.92

 

9.56

 

 

 

 

 

 

Basic Functions

Vibration

Specifications

Test Method (Random vibration)

Fix the camera at the four fixation points of the base using M2 screws.

Perform the random vibration test under the following conditions in the X, Y and Z directions for 20 minutes in each direction.

The camera vibration specification is to have no malfunction after this test.

Power spectrum density

5 to 50 Hz

4.14 m2/s3

{0.043 G2/Hz}

 

50 to 100 Hz

–36 dB/oct

 

 

 

Effective overall value

14.3 m/s2

{1.46 G}

 

 

 

Test time

20 minutes

 

 

 

 

 

Spectral Sensitivity Characteristics

27