Eclipse
When designing the housing, refer to the dimensional allowance as shown in the figure below.
˚ |
| |
97 | ˚ | |
. | ||
82 | ||
30 | ||
. | ||
| 21 |
8.92 |
| 9.56 |
|
|
|
|
|
|
Basic Functions
Vibration
Specifications
Test Method (Random vibration)
•Fix the camera at the four fixation points of the base using M2 screws.
•Perform the random vibration test under the following conditions in the X, Y and Z directions for 20 minutes in each direction.
•The camera vibration specification is to have no malfunction after this test.
Power spectrum density | 5 to 50 Hz | 4.14 m2/s3 | {0.043 G2/Hz} |
| 50 to 100 Hz | ||
|
|
| |
Effective overall value | 14.3 m/s2 | {1.46 G} | |
|
|
| |
Test time | 20 minutes |
| |
|
|
|
|
Spectral Sensitivity Characteristics
27