VISCA commands are the basis of camera control.
Timing Chart
As VISCA Command processing can only be carried out one time in a Vertical cycle, it takes the maximum 1V cycle time for an ACK/Completion to be returned. If the Command ACK/Completion communication time can be cut shorter than the1V cycle time, then every 1V cycle can receive a Command.
General Commands
Within
Query Commands
Within
Commands
•Power On/Off
Powers the camera on and off. When the power is off, the camera is able to accept only the lowest level of VISCA Commands; the display and other features are turned off.
•I/F clear
Clears the Command buffer of the FCB camera. Clearing the buffer can also be carried out from the control application software when the power is on.
•Address set
VISCA is a protocol, which normally can support a daisy chain of up to seven attached devices. However, the FCB camera does not support camera connections in a daisy chain. Therefore, whenever a camera is connected for the first time, be sure to use the address set to confirm the address.
•ID Write
Sets the camera ID.
•Mute
Blanks the screen and sends out a synchronizing signal.
•Lens Initialization
Initializes the zoom and focus of the lens. Even when power is already on, it initializes the zoom and the focus.