VISCA Device Setting
Command
Before starting control of the FCB camera, be sure to send the Address command and the IF_Clear command using the broadcast function.
For VISCA Network Administration
●Address
Sets an address of a peripheral device. Use when initializing the network and when receiving the network change message indicated below.
●Network Change
Sent from the peripheral device to the controller when a device is removed from or added to the network. The address must be
| Packet | Note |
Address | 88 30 01 FF | Always broadcasted. |
Network Change | X0 38 FF |
|
X = 9 to F: FCB camera address + 8
VISCA Interface Command
●IF_Clear
Clears the command buffers in the FCB camera and cancels the command currently being executed.
| Command Packet Reply Packet Note | ||
IF_Clear | 8X 01 00 01FF | X0 50 FF | |
IF_Clear (broadcast) | 88 01 00 01 | FF | 88 01 00 01 FF |
X = 1 to 7: FCB camera address (For inquiry packet) | |||
X = 9 to F: FCB camera address +8 | (For reply packet) |
Command List
VISCA Interface and Inquiry
●CAM_VersionInq
Returns information on the VISCA interface.
Inquiry | Inquiry Packet | Reply Packet | Description |
CAM_VersionInq | 8X 09 00 02 FF | Y0 50 GG GG | GGGG = Vender ID |
| HH HH JJ JJ | (0020: Sony) |
|
|
| KK FF | HHHH = Model ID |
|
|
| 0441 = |
|
|
| JJJJ = ROM revision |
|
|
| KK = Maximum socket # (02) |
X = 1 to 7: FCB camera address (For inquiry packet)
X = 9 to F: FCB camera address +8 (For reply packet)