Displaying the digital hours meter
Function buttons | MENU button |
To display the digital hours meter
Press the MENU button, then turn the MULTI CONTROL knob to display the required item in the time data display area.
and Maintenance 10 Chapter
PB LEVEL 1 3
REC LEVEL 1 3
2 4
2 4
R/P LEVEL CTL
VAR
LEVEL
PRESET
SHIFT
REC INHI
ON |
|
PHONES OFF | PAGE |
| |
KEY INHI |
|
ON | HOME |
| |
OFF |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| EJECT |
|
|
|
|
|
|
|
|
|
| DISPLAY | MULTI CONTROL REMOTE |
CHARACTR | EMPH | EMPH EMPH | EMPH | INPUT : ANA | HD |
|
| ||||
|
|
| |||||||||
| ON |
| 0 |
| 0 |
| CH1 IN : |
| MENU |
| |
| PB/EE |
|
|
| COND |
| |||||
|
|
|
| CH2 IN : |
|
| PUSH | ||||
| PB |
|
|
| OUT : +4 |
| RESET | ||||
| CONFI |
|
|
|
| PITCH CTL JOG/SHUTTLE | |||||
|
|
|
| MONI L : | 1 | BANK 2 |
|
| |||
| ENABLE |
|
|
| MONI R : | 2 | PREROLL |
| |||
|
|
|
|
| |||||||
| CTL/TC |
|
|
|
|
|
| ||||
| 1 |
| 2 | 3 | 4 | DOLBY NR | P ROLL |
|
| ||
| TC | 59.94i | SDI | ASMBL CONFI ON RECORDER |
|
| |||||
| ASSEMBLE |
|
| ||||||||
| OFF | LTC | DF | VITC LTC | REM:00M |
|
| ||||
| TCG SET | 00:00:00:00. |
|
| |||||||
| HOME |
|
| ||||||||
REW | PLAY | F FWD | STOP | REC | PAUSE |
|
STANDBY
To exit from the hours meter
Press the EXIT function button.
Inspection
MULTI CONTROL knob
Use the following table as a timing guide for checking and replacing components of the unit.
These intervals are not guaranteed lifetimes; the timing for replacing components depends on the particular conditions of use. In particular, depending on the degree of dirt
contamination and abrasion, pinch rollers and cleaners may require replacement earlier than suggested by this table. Note that an arrow in the table means that the component to be replaced is part of the assembly the arrow points to, which must be replaced as a whole.
No. | Replacing components | Mode |
|
| Replacement intervals (H) |
|
| ||
|
|
| 1,000 | 2,000 | 3,000 | 4,000 | 5,000 | 6,000 | 10,000 |
1 | Upper drum assembly | A |
| R |
| r |
| R |
|
|
|
|
|
|
|
|
|
|
|
2 | Slip ring | A |
| R |
| r |
| R |
|
|
|
|
|
|
|
|
|
|
|
3 | Blush | A |
| R |
| r |
| R |
|
|
|
|
|
|
|
|
|
|
|
4 | Drum assembly | A |
|
|
| R |
|
|
|
|
|
|
|
|
|
|
|
|
|
5 | Video head cleaner | B | R | R | R | R | R | R |
|
|
|
|
|
|
|
|
|
|
|
6 | Pinch roller | B | R | R | R | R | R | R |
|
|
|
|
|
|
|
|
|
|
|
7 | Gear | B |
| R |
| R |
| R |
|
|
|
|
|
|
|
|
|
|
|
8 | Tension regulator band | B |
| R |
| R |
| R |
|
|
|
|
|
|
|
|
|
|
|
9 | Timing belt (reel) | B |
|
| R |
|
| R |
|
|
|
|
|
|
|
|
|
|
|
10 | S main brake shoe | B |
|
| R |
|
| R |
|
|
|
|
|
|
|
|
|
|
|
11 | S reel motor | B |
|
|
|
|
| R |
|
|
|
|
|
|
|
|
|
|
|
12 | Coil spring | C |
|
| Replace every 20,000 times |
|
| ||
|
|
|
|
|
|
|
|
|
|
13 | LCD back light | D |
|
|
|
|
|
| R |
|
|
|
|
|
|
|
|
|
|
R: Replace
r: Replace when the arrowed component is replaced.
Mode A: See menu item H02 or H12 (drum running hours (H))
Mode B: See menu item H03 or H13 (tape running hours (H))
Mode C: See menu item H04 or H14 (threading counter (times))
Mode D: See menu item H01 (operation hours (H))
82 Regular Checks