39
DSR Series
DATA No. BIT7 BIT6 BIT5 BIT 4 BIT3 BIT2 BIT1 BIT0
0CASSETTE REF VD HARD LOCAL
OUT MISSING ERROR
1STANDBY TENSION STOP EJECT REW F.FWD REC PLAY
ON RELEASE
2SERVO TSO SHUTTLE JOG VAR REV/FWD STILL CUE UP
LOCK MODE COMPLETE
3AUTO AUDIO OUT AUDIO IN OUT IN
MODE
4SELECT EE FULL EE EDIT REVIEW AUTO EDIT PREVIEW PREROLL
ON ON OR CUE UP
5INSERT ASSEMBLE VIDEO TIME AUDIO AUDIO
CODE CH-2 CH-1
6
7VARIABLE VAR MEMORY AUDIO IN/OUT
MEMORY ACTIVE SPLIT STATUS
8LOST LOCK END OF REC
TAPE INHIBIT
9FUNCTION
ABORT
AΔ t REC/PLAY Δ t READY VAR
EXECUTE REC/PLAY
B
CDA4 DA3 DA2 DA1
D
E
F
7X.20 : STATUS DATA
This return command is returned in response to the “60.20 : STATUS SENSE” command from
the DEVICE. The DEVICE returns the following data in accordance with the request.
STATUS DATA
DATA No.0
DATA No.0/BIT-5 : CASSETTE OUT
BIT-5 will be set to “1” when there is no cassette threading on the DEVICE.
DATA No.0/BIT-4 : REFERENCE VIDEO MISSING
BIT-4 will be set to “1” when the REFERENCE VIDEO is not detected on the REF VIDEO
IN connector panel.
DATA No.0/BIT-2 : HARD ERROR
BIT-2 will be set to “1” when the following troubles (the tape is sticking to the drum, the tape
is slackening and so on).
For details, refer to the maintenance manual ERROR MESSAGE (SELF DIAGNOSTICS).