21
Setup Menu
Menu List
The following conventions are used in the menu list table.
Settings column values (e.g. ON, OFF, 0): Default settings
Execute by ENTER: Press the CONTROL knob or move the CANCEL/ENTER lever to the ENTER position to execute.

SYSTEM OPERATION menu

Note

SYSTEM OPERATION
Page name
Page No. Item Settings Description
<OUTPUT SELECT>
S01
OUTPUT CAMERA, BAR, TEST1, TEST2 Output signal selection
TEST1 and TEST2 are not selectable if there
is no communication with the camera.
PIX ENC, R, G, B, R&G, G&B, R&B,
RGB
PIX connector output signal selection
<GENLOCK PHASE>
S02
REFERENCE (NONE), (EXT IN) Reference signal input status (display only)
GENLOCK (HD), (SD) CCU GENLOCK mode, lock status, and signal
format
(HD): HD
(SD): SD
(OK), (NG) External reference signal lock status
(OK): Locked
(NG): Unlocked
External reference signal format Displayed only when a reference signal is
present.
Reference signal lock phase adjustments
H STEP When GENLOCK mode is HD:
–3.01 to 3.45µs 0.00
When GENLOCK mode is SD:
–8.29 to 9.48µs 0.00
Horizontal phase (STEP)
COARSE –99.9 to 99.9 0.0 Horizontal phase
SC PHASE 0 to 359 Subcarrier phase
V PHASE 0 to 7 Vertical phase (line)
SYNC OUT HD SYNC, SD SYNC SYNC connector output signal selection
<MULTI FORMAT>
S03

Note

FREQUENCY or
CAMERA FORMAT mode
setting changes take
effect only after the CCU
power supply is turned off
and then on again.
FREQUENCY 59.94 Hz, 50 Hz
(525 NTSC), (625 PAL)
Operating frequency selection
CAMERA FORMAT When FREQUENCY is set to
59.94 Hz: 1080/59.94i, 720/59.94P
When FREQUENCY is set to
50 Hz: 1080/50i, 720/50P
Transmission format selection