4
ICX274AQ
Bias Conditions
1Progressive scan mode, 2/8-line readout mode, 2/4-line readout mode, center scan modes (1) and (3),
and AF modes (1) and (2)
22-line addition mode and center scan mode (2)
3VL setting is the VVL voltage of the vertical clock waveform, or the same voltage as the VL power supply
for the V driver should be used.
4Substrate voltage (VSUB2) setting value indication
The substrate voltage (VSUB) for modes without line addition is generated internally.
The substrate voltage setting value for use with vertical 2-line addition is indicated by a code on the
bottom surface of the image sensor. Adjust the substrate voltage to the indicated voltage.
VSUB2 code 1-digit indication
VSUB2 code
The code and the actual value correspond as follows.
[Example] "h" indicates a VSUB2 setting of 11.6V.
5Do not apply a DC bias to the reset gate clock pin, because a DC bias is generated within the CCD.
DC characteristics
Supply current
Item
IDD
Symbol
10.0
Min. Unit RemarksTyp. Max.
mA13.07.0
J
11.8
K
12.0
L
12.2
m
12.4
N
12.6
P
12.8
R
13.0
S
13.2
U
13.4
V
13.6
W
13.8
X
14.0
Y
14.2
Z
14.4
VSUB2 code
Actual value
1
8.8
2
9.0
3
9.2
4
9.4
6
9.6
7
9.8
8
10.0
9
10.2
A
10.4
C
10.6
d
10.8
E
11.0
f
11.2
G
11.4
h
11.6
VSUB2 code
Actual value
Supply voltage
Protective transistor bias
Substrate voltage
adjustment range
Substrate voltage adjustment accuracy
Reset gate clock
Item
VDD
VL
VSUB
VSUB2
VSUB
φRG
Symbol
15.0
3
Internally generated value
Indicated
voltage
5
Min.
V
V
V
V
Unit
4
RemarksTyp. Max.
No line addition1
2-line addition2
14.55
8.8
Indicated
voltage 0.2
15.45
14.4
Indicated
voltage + 0.2