25
KV-29FX11
Center dot
RGB
H.STAT V.STAT Magnet
R
G
B
RV702
Screen
C Board
RV701
H Stat
3-2. CONVERGENCE
Preparation:
• Before start i ng this adjustment, adjust the focus, horizontal
size and vertical size.
• Minimize the Brightness setting.
• Input a dot pattern from the pattern generator.
(1) Horizontal and vertical static convergence
1. [Moving horizontally], adjust the H.STAT control so that the
Red, Green and Blue points are on top of each other at the
centre of the screen.
2. [Moving vertically], adjust the V.STAT magnet so that the
Red, Green and Blue points are o n t op of each other at t he
centre of the screen.
3. If the H.STAT variable resistor is unable to bring the Red,
Green and Bl ue points tog ether at the centre of t he screen,
adjust the h ori zontal convergence with the H.STAT variable
resi s tor an d the V.STAT magne t in th e m a nn er indic a te d be low.
[In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other].
• Tilt the V.STAT magnet and ad ju st the static convergence
by opening or closing the V.STAT ma gnet.
4. If the V.STAT magnet is moved in the direction of the a
and b arrows, the Red, Green and Blu e points move as
indicated below.