26
KV-29FX11

BMC (Hexapole)

V.STAT

Purity

RG B R G B R G B
RGBRGBRGB
RGB
B
G
R
RGB
BG
R
B
G
R
R
G
B
R
G
B
B
G
R
Tilt Direction
Operation of the BMC (Hexapole) magnet.
The respective dot position resulting fr om moving each
magnet interact, so be sure to perform adjustment whilst
tracking.
Use the H.STAT VR to adjust th e Red, Green and Blue dots
so that they coincide at the centre of the screen
(by moving the dots in the horizontal direction).

(2) Dynamic convergence adjustment.

Preparation:
Befor e starting this adjustment , ad just the horizontal and
vertical static convergence.
1. Remove the deflection yolk spacer.
2. Tilt the deflection yolk as indicated in the figure below and
optimize the convergence.
3. Re-install the deflection yolk spacer.
Note : This adjustment will affect the geometry of the
displ a y, there fore adjust to obtain th e optimum
setting.