26
KV-29FX11
BMC (Hexapole)
V.STAT
Purity
RG B R G B R G B
RGBRGBRGB
RGB
B
G
R
RGB
BG
R
B
G
R
R
G
B
R
G
B
B
G
R
Tilt Direction
• Operation of the BMC (Hexapole) magnet.
• The respective dot position resulting fr om moving each
magnet interact, so be sure to perform adjustment whilst
tracking.
Use the H.STAT VR to adjust th e Red, Green and Blue dots
so that they coincide at the centre of the screen
(by moving the dots in the horizontal direction).
(2) Dynamic convergence adjustment.
Preparation:
• Befor e starting this adjustment , ad just the horizontal and
vertical static convergence.
1. Remove the deflection yolk spacer.
2. Tilt the deflection yolk as indicated in the figure below and
optimize the convergence.
3. Re-install the deflection yolk spacer.
Note : This adjustment will affect the geometry of the
displ a y, there fore adjust to obtain th e optimum
setting.