2-2. CONVERGENCE

Before starting convergence adjustments:

1Perform FOCUS, VLIN and VSIZE adjustments.

2.Set BRIGHTNESS control to minimum.

3.Feed in dot pattern.

VERTICAL STATIC CONVERGENCE

1.Adjust V. STAT magnet to converge red, green and blue dots in the center of the screen.

Center dot R

G

B

R G B

RV701

H.STAT

V.STAT magnet

2.Tilt the V. STAT magnet and adjust static convergence to open or close the V. STAT magnet.

When the V. STAT magnet is moved in the direction of arrow a and b, red, green, and blue dots move as shown below:

1

a

a

b

b

b

B

B

 

 

G

G

 

 

R

R

2

a

a

 

 

 

R

G B

b b

B G R

3

b a a b

R

B

b G

G

B

R

KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120

HORIZONTAL STATIC CONVERGENCE

If the blue dot does not converge with the red and green dots, perform the following:

1.Move H STAT VR magnet (a) to correct insufficient H.Static convergence.

H STAT VR

V.STAT

 

BMC

PURITY

MAGNET

 

KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120

24

Page 23
Image 23
Sony KV-34FS120, KV-32FS320, KV-27FS320 Vertical Static Convergence, Horizontal Static Convergence, Stat BMC Purity