MZ-E707

3.

If NG in the overall CD adjustments, return to Reset NV and

 

perform from the electrical offset adjustment again.

 

LCD display

 

XXX NG

 

XXX: NG item No.

4.

If OK through the overall CD adjustments, then perform overall

 

MO adjustments.

 

LCD display

 

XXX CD OK

 

 

 

 

5.

Insert MO disc in the set, and press

> N

key to set the

 

Overall MO Adjustment mode. Automatic adjustments are made.

 

LCD display

5-5-5. Overall CD and MO adjustment items

1. Overall offset adjustment

Item No.

Contents

030GRV setting • Sarvo OFF • Head UP

035Laser ON/OFF electrical offset difference measurement

Completed

2. Overall CD adjustment items

Item No.

Contents

761VC,VR power voltage High/Low selection

300HPIT setting • Sarvo OFF

561SLED move to inside

562SLED move to outside

High reflection CD electrical offset adjustment

XXX MO RUN

312

Laser ON • Focus UP • VC correction ALFA offset

adjustment

XXX: Item No. for which an adjustment is being executed.

6. If NG in the overall MO adjustments, return to Reset NV and

perform the adjustment again.

LCD display

000XXX NG

XXX:NG item No.

7.If OK through the overall MO adjustments, press x key to return to the TEST MODE and terminate the Overall Adjust- ment mode.

LCD display

000MO OK

5-5-3.Resume clear method

1.Setting the testmode.

2.Set the Manual mode and set the item No.043(RESUME Clear). LCD display

043 Resume CC

3.Press the X key. LCD display

043 Res ***

After reset is completed

LCD display

043 Res Clr

5-5-4. Rewrite the NV value

After resume clear, rewrite the NV value. Microprocessor version 1.0 to 2.0 : Step 1 and 2. Microprocessor version 2.1 and later : Step 1 only

Step

Item NO.

NV value

 

 

 

1

861

0F (h)

862

0B (h)

 

 

 

 

2

863

87 (h)

864

75 (h)

 

 

 

 

313IJ offset adjustment

314FE offset adjustment

HPIT adjustment

320 Focus servo ON

324TE offset adjustment 1

321TE gain adjustment

328TWPP gain adjustment

324TE offset adjustment 1

332TE offset adjustment 2

330Tracking servo ON

336ABCD gain adjustment

337KF gain correction

338RF gain adjustment

344CD focus gain adjustment

345CD tracking gain adjustment

521CD two-axis sensitivity adjustment (inside)

522CD two-axis sensitivity adjustment (outside)

341CD focus bias adjustment

300HPIT setting • servo OFF

completed

3.Overall MO adjustment items

Item No.

Contents

761VC,VR power voltage High/Low selection

100G RV setting • Servo OFF

Low reflect MO offset adjustment

112Laser ON • Focus UP • EVC correction ALFA offset adjustment

113IJ offset adjustment

114FE offset adjustment

118

Wpp denominator adjustment

 

HPIT adjustmet

 

 

200

LPIT setting • servo OFF

 

 

561

SLED move to inside

 

 

220

Focus servo ON

224TE offset adjustment 1

221TE gain adjustment

224TE offset adjustment 1

232TE offset adjustment 2

14

Page 14
Image 14
Sony MZ-E707 service manual Mo Ok, Resume CC, 043 Res, Res Clr